There are now three types of continuous glucose monitors available. They all transmit glucose results wirelessly from a small sensor placed just beneath the skin via a transmitter whose signal is received by the monitor placed anywhere from 5 to 10 feet away. Results are sent from every minute to every 5 minutes and the trend of the readings can be shown on graphs. One, the Medtronic Realtime System®, can transmit the results into the same unit that is used as the insulin pump. However, even though the same unit acts as both monitor and pump, it is still necessary for the wearer to program and set the amount of insulin to be delivered. Studies have shown that the additional information provided by the frequently delivered values and the graphed trends reduces high and low glucose events in the wearer by about half. It is important to note that all the current continuous glucose monitors are approved only for use with and alongside conventional glucose meters. This means that before acting on the information the continuous monitor provides, you should verify it by obtaining a reading with your regular monitor. Also, the two technologies provide similar but slightly different information. The conventional monitor measures blood glucose from the blood droplet resulting from the finger prick. The continuous meter does not use blood. Instead, it measures the glucose level in the fluid bathing the tissue under the skin. This is in fact derived from the blood plasma itself, but it takes several minutes to adjust to reflect the blood level. The available continuous meters need to be calibrated twice daily (Medtronic Guardian®, Dexcom 7®) with a conventional fingerstick reading, although the newer Abbott Freestyle Navigator® needs only four calibration readings in a 5-day period. Once introduced, the sensor/transmitter can be worn for 3 (Guardian), 5 (Navigator), or 7 (Dexcom- 7) days before the sensor must be changed. Features of an available continuous monitor are shown in Figure 7 and Table 12.
The decision as to whether to get one of these monitors depends on the value to the wearer of knowing his or her
A: Applicator; R: Receiver; ST: Sensor-Transmitter
Figure 7 A continuous glucose monitor.
Table 12 Features of Two Available Continuous Glucose Monitors
Feature
|
Dexcom STS
|
Medtronic Guardian
|
Sample site
|
Subcutaneous ISF
|
Subcutaneous ISF
|
Sensor life (days)
|
7
|
6
|
User age (years)
|
>18
|
>7
|
Set-up cost ($)
|
800
|
1339
|
Clark Error Grid A&B
|
95.4%
|
96.0%
|
Probe gauge
|
25
|
22
|
Battery
|
Rechargeable
|
Disposable AAA
|
Initialization (minutes)
|
120
|
140
|
Calibration (hours)
|
2, 8, then q12
|
0.5 x 2,
then q12
|
Alarms
|
High and low
|
High and low
|
Integratable
|
No
|
Can transmit to Paradigm
insulin pump
|
Transmitter range (feet)
|
5
|
6
|
Transmitter waterproof
|
Yes
|
Yes
|
Graphs trends (hours)
|
1, 3, and 9
|
3 and 24
|