Equipment
■ Alcohol pads.
■ Gauze pads.
■ Washcloth.
■ Shaving supplies or scissors, if necessary.
■ Disposable electrodes.
■ For hardwire monitoring, add: cardiac monitor; cable with lead wires; safety pin; 1-in. tape.
■ For telemetry, add: transmitter with lead wires (with a new battery inserted before each use); pouch to carry transmitter.
Assessment
■ Check for history of dysrhythmias.
■ Assess cardiovascular status, including:
■ Heart sounds.
■ Pulse rate.
■ BP.
■ Check for the presence of pain.
■ Be Smart! Assess skin integrity of the chest before applying electrodes.
■ Skin lesions contraindicate the application of leads to the affected area.
Post-Procedure Reassessment
■ Evaluate changes in the patient’s cardiac rhythm.
■ Check skin integrity, and replace the electrodes at least every 24 hours.
Key Points
■ Plug in the monitor and turn it on. Connect the cable with lead wires into the monitor.
■ Identify electrode sites based on the monitoring system and the patient’s anatomy.
■ Gently rub the placement sites with a gauze pad until the skin reddens slightly.
■ Use an alcohol pad to clean the areas for electrode placement; allow to dry.
■ Connect lead wires to the electrodes.
■ Be Smart! If the patient’s chest is very hairy, shave small areas for the electrodes.
■ Apply the electrodes, pressing firmly.
■ Check the ECG tracing on the monitor. If necessary, adjust the gain to increase the waveform size.
■ Be Safe! Set the upper and lower heart rate alarm limits and turn them on.
■ Obtain a rhythm strip by pressing the “record” button.
■ Be Smart! If you are not getting a good reading, recheck the leads, replace leads, or move leads if necessary.
Documentation
■ Chart the date and time monitoring was instituted and the monitoring lead selected.
■ Document a rhythm strip every 8 hours and with changes in the patient’s condition according to agency policy.
■ Label the rhythm strip (if the monitor does not label it for you) with the date, time, patient’s name, and room number.
■ Indicate on the strip when symptoms and treatment interventions occurred.
■ Document the patient’s response to treatment.
The monitoring system specifies lead placement |
2 comments:
ECG/EKG machine is very powerful diagnostic tool. So there is always going to be great need of ECG / EKG Leads & Cables. Cables and Sensors is the global leader in oxygen sensors for bedside monitors and ECG and EKG cables.This leads and cables are manufactured from the branded names like Philips, Baxter, Burdick, Datascope, Criticare,MEdex, Masimo, Dragger etc
HOW I GOT CURED OF HERPES VIRUS.
Hello everyone out there, i am here to give my testimony about a herbalist called dr imoloa. i was infected with herpes simplex virus 2 in 2013, i went to many hospitals for cure but there was no solution, so i was thinking on how i can get a solution out so that my body can be okay. one day i was in the pool side browsing and thinking of where i can get a solution. i go through many website were i saw so many testimonies about dr imoloa on how he cured them. i did not believe but i decided to give him a try, i contacted him and he prepared the herpes for me which i received through DHL courier service. i took it for two weeks after then he instructed me to go for check up, after the test i was confirmed herpes negative. am so free and happy. so, if you have problem or you are infected with any disease kindly contact him on email drimolaherbalmademedicine@gmail.com. or / whatssapp --+2347081986098.
This testimony serve as an expression of my gratitude. he also have
herbal cure for, LUPUS DISEASE, JOINT PAIN, POLIO DISEASE, PARKINSON'S DISEASE, ALZHEIMER'S DISEASE, CYSTIC FIBROSIS, SCHIZOPHRENIA, CORNEAL ULCER, EPILEPSY, FETAL ALCOHOL SPECTRUM, LICHEN PLANUS, COLD SORE, SHINGLES, CANCER, HEPATITIS A, B. DIABETES 1/2, HIV/AIDS, CHRONIC PANCERATIC, CHLAMYDIA, ZIKA VIRUS, EMPHYSEMA, LOW SPERM COUNT, ENZYMA, COUGH, ULCER, ARTHRITIS, LEUKAEMIA, LYME DISEASE, ASTHMA, IMPOTENCE, BARENESS/INFERTILITY, WEAK ERECTION, PENIS ENLARGEMENT. AND SO ON.
Post a Comment