Arteriovenous
oxygen difference ....................................3.5–5.5 vol%
Aortic
pressure:
■ Systolic
...............................................................100–140 mmHg
■ Diastolic...................................................................60–80
mm Hg
■ Mean........................................................................70–90
mm Hg
Cardiac
output (CO)...............................................................4–8
L/min
Cardiac
index (CI) .........................................................2.5–4 L/min
m2
Central
venous pressure (CVP) .........................................2–6 mm Hg
Coronary
artery perfusion pressure .............................60–80 mm Hg
Left
arterial mean pressure .............................................4–12 mm Hg
Left
ventricular systolic pressure ..............................100–140 mm Hg
Left
ventricular diastolic pressure.....................................0–5 mm Hg
Left ventricular
stroke
work
index...................................................................30–50
g/beat/m2
Mean
arterial pressure (MAP) .......................................70–90 mm Hg
Oxygen
content of blood:
■ Arterial....................................................................17.5–20.5
vol%
■ Venous
...................................................................12.5–16.5
vol%
Oxygen
consumption (VO2)
......................................200–250 mL/min
Oxygen
delivery (DO2) .............................................900–1100
mL/min
Pulmonary
artery pressure:
■ Systolic
...................................................................20–30 mm Hg
■ Diastolic...................................................................10–20
mm Hg
■ Mean........................................................................10–15
mm Hg
Pulmonary
capillary wedge pressure (PCW) .................4–12 mm Hg
Right
arterial mean pressure.............................................2–6 mm Hg
Right
ventricular pressure:
■ Systolic....................................................................20–30
mm Hg
■ Diastolic.......................................................................0–5
mm Hg
■ End diastolic
...............................................................2–6 mm Hg
Pulmonary
ventricular stroke index............................5–10 g/beat/m2
Stroke
index (SI)......................................................40–50 mL/beat/m2
Stroke
volume (SV) .....................................................70–130 mL/beat
Superior
vena cava mean pressure (SVC) .......................2–6 mm Hg
Systemic
vascular resistance (SVR) ..................900–1600 dyn/s/cm-5
Systemic venous oxygen
saturation (SVO2) .......................60%–80%
Note: Reference ranges for Hemodynamic
Valves vary according to brand of laboratory assay materials used. Check normal
reference ranges from your facility’s laboratory when evaluating results.