12/24/13

Caring for a Patient With a Fiber Optic Intracranial Catheter

Goal: The patient maintains ICP less than 10 to 15 mm Hg, and CPP 60 to 90 mm Hg.

1. Review the medical orders for specific information about monitoring parameters.

2. Gather the necessary supplies and bring to the bedside stand or overbed table.

3. Perform hand hygiene and put on PPE, if indicated.

4. Identify the patient.

5. Close curtains around bed and close the door to the room, if possible. Explain what you are going to do and why you are going to do it to the patient.

6. Assess patient for any changes in neurologic status. (See Chapter 2, Health Assessment, for details of assessment.)

7. Assess ICP, MAP, and CPP at least hourly. Note ICP waveforms as shown on the monitor. Notify the primary care provider if A or B waves are present.

8. Care for the insertion site according to the institution’s policy. Assess the site for any signs of infection, such as drainage, redness, or warmth. Ensure the catheter is secured at site per facility policy.

9. Calculate the CPP, if necessary. Calculate the difference between the systemic MAP and the ICP.

10. Remove PPE, if used. Perform hand hygiene.
Read More

Caring for a Patient with an External Ventriculostomy (Intraventricular Catheter–Closed Fluid-Filled System)

Goal: The patient maintains intracranial pressure at less than 10 to 15 mm Hg, and cerebral perfusion pressure at 60 to 90 mm Hg.

1. Review the medical orders for specific information about ventriculostomy parameters.

2. Gather the necessary supplies and bring to the bedside stand or overbed table.

3. Perform hand hygiene and put on PPE, if indicated.

4. Identify the patient.

5. Close curtains around bed and close the door to the room, if possible. Explain what you are going to do and why you are going to do it to the patient.

6. Assess patient for any changes in neurologic status. (See Chapter 2, Health Assessment, for details of assessment.)

7. Assess the height of the ventriculostomy system to ensure that the stopcock is at the level of midpoint between the outer canthus of the patient’s eye and the tragus of the patient’s ear or external auditory canal (Littlejohns, 2005), using carpenter level, bubble-line level, or laser level, according to facility policy. Adjust the height of the system if needed. Move the drip chamber to the ordered height. Assess the amount of CSF in the drip chamber if the ventriculostomy is draining.

8. Zero the transducer. Turn stopcock off to the patient. Remove the cap from the transducer, being careful not to touch the end of the cap. Press and hold the calibration button on the monitor until the monitor beeps. Return the cap to the transducer. Turn the stopcock off to the drip chamber to obtain an ICP reading. After obtaining a reading, turn the stopcock off to the transducer.

9. Adjust the ventriculostomy height to prevent too much drainage, too little drainage, or inaccurate ICP readings.

10. Care for the insertion site according to the institution’s policy. Assess the site for any signs of infection, such as purulent drainage, redness, or warmth. Ensure the catheter is secured at site per facility policy.

11. Calculate the CPP, if necessary. Calculate the difference between the systemic MAP and the ICP.

12. Remove PPE, if used. Perform hand hygiene.

13. Assess ICP, MAP, and CPP at least hourly.
Read More

Caring for a Patient in Halo Traction

Goal: The patient maintains cervical alignment.

1. Review the medical record and the nursing plan of care to determine the type of device being used and prescribed care.

2. Gather the necessary supplies and bring to the bedside stand or overbed table.

3. Perform hand hygiene and put on PPE, if indicated.

4. Identify the patient.

5. Close curtains around bed and close the door to the room, if possible. Explain what you are going to do and why you are going to do it to the patient.

6. Assess the patient for possible need for nonpharmacologic, pain-reducing interventions or analgesic medication before beginning. Administer appropriate prescribed analgesic. Allow sufficient time for analgesic to achieve its effectiveness before beginning the procedure.

7. Place a waste receptacle at a convenient location for use during the procedure.

8. Adjust bed to comfortable working height, usually elbow height of the caregiver if the patient will remain in bed (VISN 8 Patient Safety Center, 2009). Alternatively, have the patient sit up, if appropriate.

9. Assist the patient to a comfortable position that provides easy access to the head. Place a waterproof pad under the head if patient is lying down.

10. Monitor vital signs and perform a neurologic assessment, including level of consciousness, motor function, and sensation, per facility policy. This is usually at least every 2 hours for 24 hours, or possibly every hour for 48 hours.

11. Examine the halo vest unit every 8 hours for stability, secure connections, and positioning. Make sure the patient’s head is centered in the halo without neck flexion or extension. Check each bolt for loosening.

12. Check the fit of the vest. With the patient in a supine position, you should be able to insert one or two fingers under the jacket at the shoulder and chest.

13. Put on nonsterile gloves, if appropriate. Remove patient’s shirt or gown. Wash the patient’s chest and back daily. Loosen the bottom Velcro straps.

14. Wring out a bath towel soaked in warm water. Pull the towel back and forth in a drying motion beneath the front. Do not use soap or lotion under the vest.

15. Thoroughly dry the skin in the same manner with a dry towel. Inspect the skin for tender, reddened areas or pressure spots. Lightly dust the skin with a prescribed
medicated powder or cornstarch.

16. Turn the patient on his or her side, less than 45 degrees if lying supine, and repeat the process on the back. Close the Velcro straps. Assist the patient with putting on a new shirt, if desired.

17. Perform a respiratory assessment. Check for respiratory impairment, such as absence of breath sounds, the presence of adventitious sounds, reduced inspiratory
effort, or shortness of breath.

18. Assess the pin sites for redness, tenting of the skin, prolonged or purulent drainage, swelling, and bowing, bending, or loosening of the pins. Monitor body
temperature.

19. Perform pin-site care. (See Skills 9-19 and 9-20.)

20. Depending on physician order and facility policy, apply the antimicrobial ointment to pin sites and apply a dressing.

21. Remove gloves and dispose of them appropriately. Raise rails, as appropriate, and place the bed in the lowest position. Assist patient to a comfortable position.

22. Remove additional PPE, if used. Perform hand hygiene.
Read More

Employing Seizure Precautions and Seizure Management

Goal: The patient remains free from injury related to seizure disorder.

1. Review the medical record and nursing plan of care for conditions that would place the patient at risk for seizures. Review the medical orders and the nursing plan of care for orders for seizure precautions.

Seizure Precautions:

2. Gather the necessary supplies and bring to the bedside stand or overbed table.

3. Perform hand hygiene and put on PPE, if indicated.

4. Identify the patient.

5. Close curtains around bed and close the door to the room, if possible. Explain what you are going to do and why you are going to do it to the patient.

6. Place the bed in the lowest position with two to three side rails elevated. Apply padding to side rails.

7. Attach oxygen apparatus to oxygen access in the wall at the head of the bed. Place nasal cannula or mask equipment in a location where it is easily reached if needed.

8. Attach suction apparatus to vacuum access in the wall at the head of the bed. Place suction catheter, oral airway, and resuscitation bag in a location where they are easily reached if needed.

9. Remove PPE, if used. Perform hand hygiene.

Seizure Management:

10. For patients with known seizures, be alert for the occurrence of an aura, if known. If the patient reports experiencing an aura, have the patient lie down.

11. Once a seizure begins, close curtains around bed and close the door to the room, if possible.

12. If the patient is seated, ease the patient to the floor.

13. Remove patient’s eyeglasses. Loosen any constricting clothing. Place something flat and soft, such as a folded blanket, under the head. Push aside furniture or other objects in area.

14. If the patient is in bed, remove the pillow and raise side rails.

15. Do not restrain patient. Guide movements, if necessary. Do not try to insert anything in the patient’s mouth or open jaws.

16. If possible, place patient on the side with the head flexed forward, head of bed elevated 30 degrees. Begin administration of oxygen, based on facility policy. Clear airway using suction, as appropriate. (Refer to Skill 14-9, Suctioning the nasopharyngeal and oropharyngeal airways, Chapter 14, Oxygenation.)

17. Provide supervision throughout the seizure.

18. Establish/maintain intravenous access, as necessary. Administer medications, as appropriate, based on medical order and facility policy.

19. After the seizure, place the patient in a side-lying position. Clear airway using suction, as appropriate.

20. Monitor vital signs, oxygen saturation, and capillary glucose as appropriate.

21. Allow the patient to sleep after the seizure. On awakening, orient and reassure the patient.

22. Remove PPE, if used. Perform hand hygiene.
Read More

Applying a Two Piece Cervical Collar

Goal: The patient’s cervical spine is immobilized, preventing further injury to the spinal cord.

1. Review the medical record and nursing plan of care to determine need for placement of a cervical collar. Identify any movement limitations.

2. Gather the necessary supplies and bring to the bedside stand or overbed table.

3. Perform hand hygiene and put on PPE, if indicated.

4. Identify the patient.

5. Close curtains around bed and close the door to the room, if possible. Explain what you are going to do and why you are going to do it to the patient.

6. Assess patient for any changes in neurologic status. (See Chapter 2 for assessment details.)

7. Place the bed at an appropriate and comfortable working height, usually elbow height of the caregiver (VISN 8 Patient Safety Center, 2009). Lower the side rails as
necessary.

8. Gently clean the face and neck with a mild soap and water. If the patient has experienced trauma, inspect the area for broken glass or other material that could cut the patient or the nurse. Pat the area dry.

9. Have a second caregiver in position to hold the patient’s head firmly on either side above the ears. Measure from the bottom of the chin to the top of the sternum, and measure around the neck. Match these height and circumference measurements to the manufacturer’s recommended size chart.

10. Slide the flattened back portion of the collar under the patient’s head. The center of the collar should line up with the center of the patient’s neck. Do not allow the patient’s head to move when passing the collar under the head.

11. Place the front of the collar centered over the chin, while ensuring that the chin area fits snugly in the recess. Be sure that the front half of the collar overlaps the back half. Secure Velcro straps on both sides. Check to see that at least one finger can be inserted between collar and patient’s neck.

12. Raise the side rails. Place the bed in lowest position. Make sure the call bell is in reach.

13. Reassess the patient’s neurologic status and comfort level.

14. Remove PPE, if used. Perform hand hygiene.

15. Check the skin under the cervical collar at least every 4 hours for any signs of skin breakdown. Remove the top half of the collar daily and cleanse the skin under the collar. When the collar is removed, have a second person immobilize the cervical spine.
Read More

Logrolling a Patient

Goal: The patient’s spine remains in proper alignment, thereby reducing the risk for injury.

1. Review the medical record and nursing plan of care for activity orders and conditions that may influence the patient’s ability to move or to be positioned. Assess for tubes, IV lines, incisions, or equipment that may alter the positioning procedure. Identify any movement limitations.

2. Perform hand hygiene and put on PPE, if indicated.

3. Identify the patient.

4. Close curtains around bed and close the door to the room, if possible. Explain the purpose of the logrolling technique and what you are going to do, even if the patient is not conscious. Answer any questions.

5. Place the bed at an appropriate and comfortable working height, usually elbow height of the caregiver (VISN 8 Patient Safety Center, 2009).

6. Position at least one caregiver on one side of the bed and the two other caregivers on the opposite side of the bed. If a cervical collar is not in place, position one caregiver at the top of the bed, at the patient’s head. Place the bed in flat position. Lower the side rails. Place a small pillow between the patient’s knees.

7. If a friction-reducing sheet is not in place under the patient, take the time to place one at this time, to facilitate future movement of the patient.

8. If the patient can move the arms, ask the patient to cross the arms on the chest. Roll or fanfold the friction-reducing sheet close to the patient’s sides and grasp it. In unison, gently slide the patient to the side of the bed opposite to that which the patient will be turned.

9. Make sure the friction-reducing sheet under the patient is straight and wrinkle free.

10. If necessary, reposition personnel to ensure two stand on the side of the bed to which the patient is turning. The third helper stands on the other side. Grasp the frictionreducing sheet at hip and shoulder level.

11. Have everyone face the patient. On a predetermined signal, turn the patient by holding the friction-reducing sheet taut to support the body. The caregiver at the patient’s head should firmly hold the patient’s head on either side, directly above the ears. Turn the patient as a unit in one smooth motion toward the side of the bed with the two nurses. The patient’s head, shoulders, spine, hips, and knees should turn simultaneously.

12. Once the patient has been turned, use pillows to support the patient’s neck, back, buttocks, and legs in straight alignment in a side-lying position. Raise the side rails, as appropriate.

13. Stand at the foot of the bed and assess the spinal column. It should be straight, without any twisting or bending. Place the bed in the lowest position. Ensure that the call bell and telephone are within reach. Replace covers. Lower bed height.

14. Reassess the patient’s neurologic status and comfort level.

15. Remove PPE, if used. Perform hand hygiene.
Read More