12/24/13

Obtaining an Arterial Blood Specimen for Blood Gas Analysis

Goal: The blood sample is obtained from the artery without damage to the artery.

1. Gather the necessary supplies. Check product expiration dates. Identify ordered arterial blood gas analysis. Check the chart to make sure the patient has not been suctioned within the past 15 minutes. Check facility policy and/or procedure for guidelines on administering local anesthesia for arterial punctures. Administer anesthetic and allow sufficient time for full effect before beginning procedure (American Association of Critical Care Nurses [AACN], 2005; Hudson, et al., 2006).

2. Bring necessary equipment to the bedside stand or overbed table.

3. Perform hand hygiene and put on PPE, if indicated.

4. Check the patient’s identification and confirm the patient’s identity. Tell the patient you need to collect an arterialblood sample, and explain the procedure. Tell the patient that the needlestick will cause some discomfort but that he or she must remain still during the procedure.

5. Close curtains around bed and close the door to the room, if possible.

6. Check specimen label with the patient’s identification bracelet. Label should include patient’s name and identification number, time specimen was collected, route of collection, identification of person obtaining the sample, amount of oxygen the patient is receiving, and any other information required by agency policy.

7. Provide for good light. Artificial light is recommended. Place a trash receptacle within easy reach.

8. If the patient is on bed rest, ask him or her to lie in a supine position, with the head slightly elevated and the arms at the sides. Ask the ambulatory patient to sit in a chair and support the arm securely on an armrest or a table. Place a waterproof pad under the site and a rolled towel under the wrist.

9. Perform Allen’s test before obtaining a specimen from the radial artery:
a. Have the patient clench the wrist to minimize blood flow into the hand.
b. Using your index and middle fingers, press on the radial and ulnar arteries. Hold this position for a few seconds.
c. Without removing your fingers from the arteries, ask the patient to unclench the fist and hold the hand in a relaxed position. The palm will be blanched because pressure from your fingers has impaired the normal blood flow.
d. Release pressure on the ulnar artery. If the hand becomes flushed, which indicates that blood is filling the vessels, it is safe to proceed with the radial artery puncture. This is considered a positive test. If the hand does not flush, perform the test on the other arm.

10. Put on unsterile gloves. Locate the radial artery and lightly palpate it for a strong pulse.

11. Clean the site with the antimicrobial swab. If using chlorhexidine, use a back-and-forth motion, applying friction for 30 seconds to the site, or use the procedure recommended by the manufacturer. Allow the site to dry. After disinfection, do not palpate the site unless sterile gloves are worn.

12. Stabilize the hand with the wrist extended over the rolled towel, palm up. Palpate the artery above the puncture site with the index and middle fingers of your nondominant hand while holding the syringe over the puncture site with your dominant hand. Do not directly touch the area to be punctured.

13. Hold the needle bevel up at a 45-degree angle at the site of maximal pulse impulse, with the shaft parallel to the path of the artery. (When puncturing the brachial artery, hold the needle at a 60-degree angle.)

14. Puncture the skin and arterial wall in one motion. Watch for blood backflow in the syringe. The pulsating blood will flow into the syringe. Do not pull back on the plunger. Fill the syringe to the 5-mL mark.

15. After collecting the sample, withdraw the syringe while your nondominant hand is beginning to place pressure proximal to the insertion site with the 2 2 gauze. Press a gauze pad firmly over the puncture site until the bleeding stops at least 5 minutes. If the patient is receiving anticoagulant therapy or has a blood dyscrasia, apply pressure for 10 to 15 minutes; if necessary, ask a coworker to hold the gauze pad in place while you prepare the sample for transport to the laboratory, but do not ask the patient to hold the pad.

16. When the bleeding stops and the appropriate time has lapsed, apply a small adhesive bandage or small pressure dressing (fold a 2 2 gauze into fourths and firmly apply tape, stretching the skin tight).

17. Once the sample is obtained, check the syringe for air bubbles. If any appear, remove them by holding the syringe upright and slowly ejecting some of the blood onto a 2 2 gauze pad.

18. Engage the needle guard and remove the needle. Place the airtight cap on the syringe. Gently rotate the syringe to ensure that heparin is well distributed. Do not shake. Insert the syringe into a cup or bag of ice.

19. Place label on the syringe per facility policy. Place iced syringe in plastic, sealable biohazard bag.

20. Discard the needle in sharps container. Remove gloves and perform hand hygiene.

21. Remove other PPE, if used. Perform hand hygiene.

22. Transport the specimen to the laboratory immediately.
Read More

Obtaining a Venous Blood Specimen for Culture and Sensitivity

Goal: An uncontaminated specimen is obtained without causing anxiety, injury, or infection to the patient.

1. Gather the necessary supplies. Check product expiration dates. Identify ordered number of blood culture sets and select the appropriate blood-collection bottles (at least one anaerobic and one aerobic bottle). If tests are ordered in addition to the blood cultures, collect the blood-culture specimens before other specimens.

2. Bring necessary equipment to the bedside stand or overbed table.

3. Perform hand hygiene and put on PPE, if indicated.

4. Identify the patient. Explain the procedure. Allow the patient time to ask questions and verbalize concerns about the venipuncture procedure.

5. Close curtains around bed and close the door to the room, if possible.

6. Check specimen label with the patient’s identification bracelet. Label should include patient’s name and identification number, time specimen was collected, route of collection, identification of person obtaining the sample, and any other information required by agency policy.

7. Provide for good light. Artificial light is recommended. Place a trash receptacle within easy reach.

8. Assist the patient to a comfortable position, either sitting or lying. If the patient is lying in bed, raise the bed to a comfortable working height, usually elbow height of the caregiver (VISN 8 Patient Safety Center, 2009).

9. Determine the patient’s preferred site for the procedure based on his or her previous experience. Expose the arm, supporting it in an extended position on a firm surface, such as a tabletop. Position self on the same side of the patient as the site selected. Apply a tourniquet to the upper arm on the chosen side approximately 3 to 4 inches above the potential puncture site. Apply sufficient pressure to impede venous circulation, but not arterial blood flow.
10. Put on unsterile gloves. Assess the veins using inspecti

11. Release the tourniquet. Check that the vein has decompressed (Lavery & Ingram, 2005).

12. Attach the butterfly needle extension tubing to the Vacutainer device.

13. Move collection bottles to a location close to arm, with bottles sitting upright on tabletop.

14. Clean the patient’s skin at the selected puncture site with the antimicrobial swab, according to facility policy. If using chlorhexidine, use a back-and-forth motion, applying friction for 30 seconds to the site, or use the procedure recommended by the manufacturer. Allow the site to dry.

15. Using a new antimicrobial swab, clean the stoppers of the culture bottles with the appropriate antimicrobial, per facility policy. Cover bottle top with sterile gauze square, based on facility policy.

16. Reapply the tourniquet approximately 3 to 4 inches above the identified puncture site. Apply sufficient pressure to impede venous circulation, but not arterial blood flow. After disinfection, do not palpate the venipuncture site unless sterile gloves are worn.

17. Hold the patient’s arm in a downward position with your nondominant hand. Align the butterfly needle with the chosen vein, holding the needle in your dominant hand. Use the thumb or first finger of your nondominant hand to apply pressure and traction to the skin just below the identified puncture site. Do not touch the insertion site.

18. Inform the patient that he or she is going to feel a pinch. With the bevel of the needle up, insert the needle into the vein at a 15-degree angle to the skin (Fischbach & Dunning, 2006). You should see a flash of blood in the extension tubing close to the needle when the vein is entered.

19. Grasp the butterfly needle securely to stabilize it in the vein with your nondominant hand, and push the Vacutainer onto the first collection bottle (anaerobic bottle), until the rubber stopper on the collection bottle is punctured. You will feel the bottle push into place on the puncture device. Blood will flow into the bottle automatically.

20. Remove the tourniquet as soon as blood flows adequately into the bottle.

21. Continue to hold the butterfly needle in place in the vein. Once first bottle is filled, remove it from the Vacutainer and insert the second bottle. After the blood culture specimens are obtained, continue to fill any additional required tubes, removing one and inserting another. Gently rotate each bottle and tube as you remove it.

22. After you have drawn all required blood samples, remove the last collection tube from the Vacutainer. Place a gauze pad over the puncture site and slowly and gently remove the needle from the vein. Engage needle guard. Do not apply pressure to the site until the needle has been fully removed.

23. Apply gentle pressure to the puncture site for 2 to 3 minutes or until bleeding stops.

24. After bleeding stops, apply an adhesive bandage.

25. Remove equipment and return patient to a position of comfort. Raise side rail and lower bed.

26. Discard Vacutainer and butterfly needle in sharps container.

27. Remove gloves and perform hand hygiene.

28. Place label on the container, per facility policy. Place containers in plastic, sealable biohazard bag. Refer to facility policy regarding the need for separate biohazard bags for blood culture specimens and other blood specimens.

29. Check the venipuncture site to see if a hematoma has developed.

30. Remove other PPE, if used. Perform hand hygiene.

31. Transport the specimen to the laboratory immediately. If immediate transport is not possible, check with laboratory personnel or policy manual as to appropriate handling.
Read More

Using Venipuncture to Collect a Venous Blood Sample for Routine Testing

Goal: An uncontaminated specimen is obtained without causing anxiety, injury, or infection to the patient

1. Gather the necessary supplies. Check product expiration dates. Identify ordered tests and select the appropriate blood-collection tubes.

2. Bring necessary equipment to the bedside stand or overbed table.

3. Perform hand hygiene and put on PPE, if indicated.

4. Identify the patient. Explain the procedure. Allow the patient time to ask questions and verbalize concerns about the venipuncture procedure.

5. Close curtains around bed and close the door to the room, if possible.

6. Check the specimen label with the patient’s identification bracelet. Label should include the patient’s name and identification number, time specimen was collected, route of collection, identification of the person obtaining the sample, and any other information required by agency policy.

7. Provide for good light. Artificial light is recommended. Place a trash receptacle within easy reach.

8. Assist the patient to a comfortable position, either sitting or lying. If the patient is lying in bed, raise the bed to a comfortable working height, usually elbow height of the caregiver (VISN 8 Patient Safety Center, 2009).

9. Determine the patient’s preferred site for the procedure based on his or her previous experience. Expose the arm, supporting it in an extended position on a firm surface, such as a tabletop. Position self on the same side of the patient as the site selected. Apply a tourniquet to the upper arm on the chosen side approximately 3 to 4 inches above the potential puncture site. Apply sufficient pressure to impede venous circulation but not arterial blood flow.

10. Put on gloves. Assess the veins using inspection and palpation to determine the best puncture site. Refer to the Assessment information above.

11. Release the tourniquet. Check that the vein has decompressed (Lavery & Ingram, 2005).

12. Attach the needle to the Vacutainer device. Place first blood-collection tube into the Vacutainer, but not engaged in the puncture device in the Vacutainer.

13. Clean the patient’s skin at the selected puncture site with the antimicrobial swab. If using chlorhexidine, use a back-andforth motion, applying friction for 30 seconds to the site, or use the procedure recommended by the manufacturer. If using alcohol, wipe in a circular motion spiraling outward. Allow the skin to dry before performing the venipuncture. Alternately, the skin can be dried with a sterile gauze (Fischbach & Dunning, 2009). Check facility policy.

14. Reapply the tourniquet approximately 3 to 4 inches above the identified puncture site. Apply sufficient pressure to impede venous circulation but not arterial blood flow.

15. Hold the patient’s arm in a downward position with your nondominant hand. Align the needle and Vacutainer device with the chosen vein, holding the Vacutainer and needle in your dominant hand. Use the thumb or first finger of your nondominant hand to apply pressure and traction to the skin just below the identified puncture site.

16. Inform the patient that he or she is going to feel a pinch. With the bevel of the needle up, insert the needle into the vein at a 15-degree angle to the skin (Fischbach & Dunning, 2009).

17. Grasp the Vacutainer securely to stabilize it in the vein with your nondominant hand, and push the first collection tube into the puncture device in the Vacutainer, until the rubber stopper on the collection tube is punctured. You will feel the tube push into place on the puncture device. Blood will flow into the tube automatically.

18. Remove the tourniquet as soon as blood flows adequately into the tube.

19. Continue to hold Vacutainer in place in the vein and continue to fill the required tubes, removing one and inserting another. Gently rotate each tube as you remove it.

20. After you have drawn all required blood samples, remove the last collection tube from the Vacutainer. Place a gauze pad over the puncture site and slowly and gently remove the needle from the vein. Engage needle guard. Do not apply pressure to site until the needle has been fully removed.

21. Apply gentle pressure to the puncture site for 2 to 3 minutes or until bleeding stops.

22. After bleeding stops, apply an adhesive bandage.

23. Remove equipment and return the patient to a position of comfort. Raise side rail and lower bed.

24. Discard Vacutainer and needle in sharps container.

25. Remove gloves and perform hand hygiene.

26. Place label on the container per facility policy. Place container in plastic, sealable biohazard bag.

27. Check the venipuncture site to see if a hematoma has developed.

28. Remove other PPE, if used. Perform hand hygiene.

29. Transport the specimen to the laboratory immediately. If immediate transport is not possible, check with laboratory personnel or policy manual whether refrigeration is contraindicated.
Read More

Obtaining a Urine Specimen From an Indwelling Urinary Catheter

Goal: An adequate amount of urine is obtained from the patient without contamination or adverse effect; the patient experiences minimal anxiety during the collection process; and the patient demonstrates an understanding of the reason for the specimen.

1. Bring necessary equipment to the bedside stand or overbed table.

2. Perform hand hygiene and put on PPE, if indicated.

3. Identify the patient. Explain the procedure to the patient.

4. Check the specimen label with the patient’s identificationbracelet. Label should include patient’s name and identification number, time specimen was collected, route of collection, identification of person obtaining the sample, and any other information required by agency policy.

5. Close curtains around bed and close the door to the room, if possible.

6. Put on unsterile gloves.

7. Clamp the catheter drainage tubing or bend it back on itself distal to the port. If an insufficient amount of urine is present in the tubing, allow the tubing to remain clamped up to 30 minutes, to collect a sufficient amount of urine, unless contraindicated (Fischbach & Dunning, 2006). Remove lid
from specimen container, keeping the inside of the container and lid free from contamination.

8. Cleanse aspiration port with alcohol wipe and allow port to air dry.

9. Insert the needle or blunt-tipped cannula into the port, or attach the syringe to the needleless port. Slowly aspirate enough urine for specimen (usually 10 mL is adequate; check facility requirements). Remove the needle, blunttipped cannula, or syringe from the port. Engage the needle guard. Unclamp the drainage tubing.

10. If a needle or blunt-tipped cannula was used on the syringe, remove from the syringe before emptying the urine from the syringe into the specimen cup. Place the needle into sharps collection container. Slowly inject urine into specimen container. Replace lid on container. Dispose of syringe appropriately.

11. Remove gloves and perform hand hygiene.

12. Place label on the container per facility policy. Place container in plastic sealable biohazard bag.

13. Remove other PPE, if used. Perform hand hygiene.

14. Transport the specimen to the laboratory as soon as possible. If unable to take the specimen to laboratory immediately, refrigerate it.
Read More

Collecting a Urine Specimen (Clean Catch, Midstream) for Urinalysis and Culture

Goal: An adequate amount of urine is obtained from the patient without contamination.

1. Bring necessary equipment to the bedside stand or overbed table.

2. Perform hand hygiene and put on PPE, if indicated.

3. Identify the patient. Explain the procedure to the patient. If the patient can perform the task without assistance after instruction, leave the container at bedside with instructions to call the nurse as soon as a specimen is produced.

4. Have the patient perform hand hygiene, if performing selfcollection.

5. Check the specimen label with the patient’s identification bracelet. Label should include patient’s name and identification number, time specimen was collected, route of collection, identification of the person obtaining sample, and any other information required by agency policy.

6. Close curtains around bed and close the door to the room, if possible.

7. Put on unsterile gloves. Assist the patient to the bathroom, or onto the bedside commode or bedpan. Instruct the patient not to defecate or discard toilet paper into the urine.

8. Instruct the female patient to separate the labia for cleaning of the area and during collection of urine. Female patients should use the towelettes or wet washcloth to clean each side of the urinary meatus, then the center over the meatus, from front to back, using a new wipe or a clean area of the washcloth for each stroke. Male patients should use a towelette to clean the tip of the penis, wiping in a circular motion away from the urethra. Instruct the uncircumcised male patient to retract the foreskin before cleaning and during collection.

9. Have patient void a small amount of urine into the toilet, bedpan, or commode. The patient should then stop urinating briefly, then void into collection container. Collect specimen (10 to 20 mL is sufficient), and then finish voiding. Do not touch the inside of the container or the lid.

10. Place lid on container. If necessary, transfer the specimen to appropriate containers for ordered test, according to facility policy.

11. Assist the patient from the bathroom, off the commode, or off the bedpan. Provide perineal care, if necessary.

12. Remove gloves and perform hand hygiene.

13. Place label on the container per facility policy. Place container in plastic, sealable biohazard bag.

14. Remove other PPE, if used. Perform hand hygiene.

15. Transport the specimen to the laboratory as soon as possible. If unable to take the specimen to the laboratory immediately, refrigerate it.
Read More

Collecting a Sputum Specimen for Culture

Goal: The patient produces an adequate sample from the lungs.

1. Bring necessary equipment to the bedside stand or overbed table.

2. Perform hand hygiene and put on PPE, if indicated.

3. Identify the patient. Explain the procedure to the patient. If the patient might have pain with coughing, administer pain medication, if ordered. If the patient can perform the task without assistance after instruction, leave the container at bedside with instructions to call the nurse as soon as specimen is produced.

4. Check specimen label with the patient’s identification bracelet. Label should include patient’s name and identification number, time specimen was collected, route of collection, identification of the person obtaining the sample, and any other information required by agency policy.

5. Close curtains around bed and close the door to the room, if possible.

6. Put on disposable gloves and goggles.

7. Adjust the bed to a comfortable working height, usually elbow height of the caregiver (VISN 8 Patient Safety Center, 2009). Lower side rail closest to you. Place patient in semi-Fowler’s position. Have patient clear nose and throat and rinse mouth with water before beginning procedure.

8. Instruct the patient to inhale deeply two or three times and cough with exhalation. If the patient has had abdominal surgery, assist the patient to splint abdomen.

9. If the patient produces sputum, open the lid to the container and have the patient expectorate the specimen into container.

10. If patient believes he or she can produce more of the specimen, have the patient repeat the procedure.

11. Close lid to container. Offer oral hygiene to the patient.

12. Remove equipment and return the patient to a position of comfort. Raise side rail and lower bed.

13. Remove goggles and gloves. Perform hand hygiene.

14. Place label on the container per facility policy. Place container in plastic, sealable biohazard bag.

15. Remove other PPE, if used. Perform hand hygiene.

16. Transport the specimen to the laboratory immediately. If immediate transport is not possible, check with laboratory personnel or policy manual whether refrigeration is contraindicated.
Read More

Obtaining a Nasopharyngeal Swab

Goal: An uncontaminated specimen is obtained without injury to the patient and sent to the laboratory promptly.

1. Bring necessary equipment to the bedside stand or overbed table. Check the expiration date on the swab package.

2. Perform hand hygiene and put on PPE, if indicated.

3. Identify the patient. Discuss with patient the need for a nasal swab. Explain to patient the process by which the specimen will be collected.

4. Check the specimen label with the patient’s identification bracelet. Label should include patient’s name and identification number, time specimen was collected, route of collection, identification of person obtaining the sample, and any other information required by agency policy.

5. Close curtains around bed or close the door to the room, if possible.

6. Put on nonsterile gloves.

7. Ask the patient to cough and then to tip his or her head back. Assist, as necessary.

8. Peel open the swab packaging to expose the swab and collection tube. Remove the cap from the collection tube and discard. Remove the swab from packaging by grasping the exposed end. Take care not to contaminate the swab by touching it to any other surface.

9. Ask the patient to open the mouth. Inspect the back of the patient’s throat using the tongue depressor.

10. Continue to observe the nasopharynx and insert the swab approximately 6 inches (adult) through one naris to the nasopharynx. Rotate the swab. Leave the swab in the nasopharynx for 15 to 30 seconds and remove. Take care not to touch the swab to the patient’s tongue or sides of the nostrils.

11. Insert the swab into the collection tube, taking care not to touch any other surface.

12. Dispose of used equipment per facility policy. Remove gloves. Perform hand hygiene.

13. Place label on the collection tube per facility policy. Place container in plastic, sealable biohazard bag.

14. Remove other PPE, if used. Perform hand hygiene.

15. Transport the specimen to the laboratory immediately. If immediate transport is not possible, check with laboratory personnel or policy manual whether refrigeration is contraindicated.
Read More

Obtaining a Nasal Swab

Goal: An uncontaminated specimen is obtained without injury to the patient and sent to the laboratory promptly.

1. Bring necessary equipment to the bedside stand or overbed table. Check the expiration date on the swab package.

2. Perform hand hygiene and put on PPE, if indicated.

3. Identify the patient. Discuss with the patient the need for a nasal swab. Explain to the patient the process by which the specimen will be collected.

4. Check specimen label with patient identification bracelet. Label should include patient’s name and identification number, time specimen was collected, route of collection, identification of the person obtaining the sample, and any other information required by agency policy.

5. Close curtains around bed or close the door to the room, if possible.

6. Put on nonsterile gloves.

7. Ask the patient to tip his or her head back. Assist as necessary.

8. Peel open the swab packaging to expose the swab and collection tube. Remove the white plug from the collection tube and discard. Remove the swab from packaging by
grasping the exposed end. Take care not to contaminate the swab by touching it to any other surface. Moisten with sterile water, depending on facility policy.

9. Insert swab 2 cm into one naris and rotate against the anterior nasal mucosa for 3 seconds or five rotations, depending on facility policy.

10. Remove the swab and repeat in the second naris, using the same swab.

11. Insert the swab fully into the collection tube, taking care not to touch any other surface. The handle end of the swab should fit snugly into the collection tube.

12. Dispose of used equipment per facility policy. Remove gloves. Perform hand hygiene.

13. Place label on the collection tube per facility policy. Place container in plastic, sealable biohazard bag.

14. Remove other PPE, if used. Perform hand hygiene.

15. Transport specimen to the laboratory immediately. If immediate transport is not possible, check with laboratory personnel or policy manual whether refrigeration is
contraindicated.
Read More

Obtaining a Capillary Blood Sample for Glucose Testing

Goal: The blood glucose level is measured accurately without adverse effect.

1. Check the patient’s medical record or nursing plan of care for monitoring schedule. You may decide that additional testing is indicated based on nursing judgment and the patient’s condition.

2. Gather equipment.

3. Perform hand hygiene and put on PPE, if indicated.

4. Identify the patient. Explain the procedure to the patient and instruct the patient about the need for monitoring blood glucose.

5. Close curtains around bed and close the door to the room, if possible.

6. Turn on the monitor.

7. Enter the patient’s identification number, if required, according to facility policy.

8. Put on nonsterile gloves.

9. Prepare lancet using aseptic technique.

10. Remove test strip from the vial. Recap container immediately. Test strips also come individually wrapped. Check that the code number for the strip matches code number on the monitor screen.

11. Insert the strip into the meter according to directions for that specific device.

12. For adult, massage side of finger toward puncture site.

13. Have the patient wash hands with soap and warm water and dry thoroughly. Alternately, cleanse the skin with an alcohol swab. Allow skin to dry completely.

14. Hold lancet perpendicular to skin and pierce site with lancet.

15. Wipe away first drop of blood with gauze square or cotton ball if recommended by manufacturer of monitor.

16. Encourage bleeding by lowering the hand, making use of gravity. Lightly stroke the finger, if necessary, until sufficient amount of blood has formed to cover the sample area on the strip, based on monitor requirements (check instructions for monitor). Take care not to squeeze the finger, not to squeeze at puncture site, or not to touch puncture site or blood.

17. Gently touch a drop of blood to pad to the test strip without smearing it.

18. Press time button if directed by manufacturer.

19. Apply pressure to puncture site with a cotton ball or dry gauze. Do not use alcohol wipe.

20. Read blood glucose results and document appropriately at bedside. Inform patient of test result.

21. Turn off meter, remove test strip, and dispose of supplies appropriately. Place lancet in sharps container.

22. Remove gloves and any other PPE, if used. Perform hand hygiene.
Read More

Collecting a Stool Specimen for Culture

Goal: An uncontaminated specimen is obtained and sent to the laboratory promptly.

1. Gather necessary equipment and bring to the bedside.

2. Perform hand hygiene and put on PPE, if indicated.

3. Identify the patient. Discuss with the patient the need for a stool sample. Explain to the patient the process by which the stool will be collected, either from a bedpan, commode, or plastic receptacle in the toilet to catch stool without urine. Instruct the patient to void first and not to discard toilet paper with stool. Tell the patient to call you as soon as a bowel movement is completed.

4. Check specimen label with the patient’s identification bracelet. Label should include patient’s name and identification number, time specimen was collected, route of collection, identification of the person obtaining the sample, and any other information required by agency policy.

5. After the patient has passed a stool, put on gloves. Use the tongue blades to obtain a sample, free of blood or urine, and place it in the designated clean container.

6. Collect as much of the stool as possible to send to the laboratory.

7. Place lid on container. Dispose of used equipment per facility policy. Remove gloves and perform hand hygiene.

8. Place label on the container per facility policy. Place container in plastic, sealable biohazard bag.

9. Remove other PPE, if used. Perform hand hygiene.

10. Transport the specimen to the laboratory while stool is still warm. If immediate transport is impossible, check with laboratory personnel or policy manual whether refrigeration is contraindicated.
Read More

Testing Stool for Occult Blood

Goal: An uncontaminated stool sample is obtained, following collection guidelines, and then transported to the laboratory within the recommended time frame, without adverse effect.

1. Bring necessary equipment to the bedside stand or overbed table.

2. Perform hand hygiene and put on PPE, if indicated.

3. Identify the patient. Discuss with the patient the need for a stool sample. Explain to the patient the process by which the stool will be collected, either from a bedpan, commode, or plastic receptacle in the toilet.

4. If sending the specimen to the laboratory, check specimen label with patient identification bracelet. Label should include patient’s name and identification number, time specimen was collected, route of collection, identification of the person obtaining the sample, and any other information required by agency policy.

5. Close curtains around bed or close the door to the room, if possible.

6. Place the plastic collection receptacle in the toilet, if applicable. Assist the patient to the bathroom or onto the bedside commode, or assist the patient onto the bedpan. Instruct the patient not to urinate or discard toilet paper with the stool.

7. After the patient defecates, assist the patient out of the bathroom, off the commode, or remove the bedpan. Perform hand hygiene and put on disposable gloves.

8. With wooden applicator, apply a small amount of stool from the center of the bowel movement onto one window of the Hemoccult testing card. With opposite end of wooden applicator, obtain another sample of stool from another area and apply a small amount of stool onto second window of Hemoccult card.

9. Close flap over stool samples.

10. If sending to the laboratory, label the specimen card per facility policy. Place in a sealable plastic biohazard bag and send to the laboratory immediately.

11. If testing at bedside, open flap on opposite side of card and place two drops of developer over each window and wait the time stated in the manufacturer’s instructions.

12. Observe card for any blue areas.

13. Discard Hemoccult testing slide appropriately, according to facility policy. Remove gloves and any other PPE, if used. Perform hand hygiene.
Read More